LAMINAR FLOW
 












 

LAMINAR FLOW CABINET

The Laminar Air Flow Cabinet is a standard air flow model used in most laboratories. It provides only product safety and not user or environmental safety. The area of work table will be under Class 100 clean air working condition and the cabinet air will be vented / exhausted out through the front opening.

 

 

MATERIAL OF CONSTRUCTION

Electro-galvanised (G.I) sheet metal with powder coat finish.
CRCA sheet with powder coat finish
Water proof plywood with lamination
Stainless steel.
MDF board with lamination

Unit consists of HEPA Filter, PRE Filter, Blower Assembly, S.S. Table top, U.V. Lamp, Transparent Front Door, Manometer, Gascock, Side View Glass Panel, Castor Wheel and Level Jack.

TECHNICAL SPECIFICATION

Cleanliness : Class 100
Particle retention : 0.3 micron & above
Velocity : 90 ± 20%
Standard : US Federal Standard 209 E
Noise level : 65 db ± 5%
Illumination : 750 to 800 lumen.
Power supply : 220 V single phase 50 cycle.

APPLICATION

Laminar flow cabinet configuration finds extensive application in Scientific, Medical and Pharmacies. Ideal for Microbiology, Biotechnology, Research work for Institution and Semi Conductor Industry for performing R & D or sterile work under clean working condition.

top
 
HORIZONTAL LAMINAR FLOW CABINET
 

Horizontal Laminar Flow Cabinet direct the air through PRE filter at the bottom level of the cabinet and the air flows horizontally through HEPA filter towards the work area. Again the air is discharged back to the room. Thus horizontal laminar flow cabinet provides only product protection.

 

 

Floor Standing Model
Table Top Model
Working area
THFS 222
THTT 222
2’ x 2’ x 2’
THFS 322
THTT 322
3’ x 2’ x 2’
THFS 422
THTT 422
4’ x 2’ x 2’
THFS 622
THTT 622
6’ x 2’ x 2’

 

top
 
VERTICAL LAMINAR FLOW CABINET
 

Vertical Laminar Airflow directs the air through PRE filter from top / bottom level of cabinet and the air flows vertical down flow through HEPA filter towards the work area. Again the air is discharged back to the room. Thus vertical laminar flow cabinet provides only product protection.

 

 

Floor Standing Model
Table Top Model
Working area
TVFS 222
TVTT 222
2’ x 2’ x 2’
TVFS 322
TVTT 322
3’ x 2’ x 2’
TVFS 422
TVTT 422
4’ x 2’ x 2’
TVFS 622
TVTT 622
6’ x 2’ x 2’

 

top
 
LAMINAR FLOW WITH EXHAUST SYSTEM
 

In Vertical Laminar Flow Cabinet, an additional Exhaust System is provided to exhaust the contaminated air out.

 

MODEL NO.
Working area(L x D x H)
TVES 222
2’ x 2’ x 2’
TVES 322
3’ x 2’ x 2’
TVES 422
4’ x 2’ x 2’
TVES 622
6’ x 2’ x 2’