BIO SAFETY CABINETS
 












 

BIO SAFETY CABINET - CLASS I

The Bio Safety Cabinet is a safer version of the Laminar Air Flow Cabinet. Here 100% air is exhausted through HEPA filter to the outside or into the room. Provides only user and environmental safety and not product safety.

 

 

MATERIAL OF CONSTRUCTION

Electro – galvanised (G.I) sheet metal with powder coat finish
CRCA sheet with powder coat finish
Water proof plywood with lamination
Fully Stainless steel

TECHNICAL SPECIFICATION

Cleanliness : Class 100
Particle retention : 0.3 micron & above
Filter Face Velocity : 90 ± 20 FPM
Standard : US Federal Standard 209 E
Noise Level : 65 dB ± 5 %
Illumination : 750 to 800 lumen
Power supply : 220 v single phase 50 cycle

APPLICATION

Most suitable for bacteriological, toxicology, where the presence of highly air borne particles, bacteria and viral need to be controlled to provide clean working condition.

MODEL NO.
Working area(L x D x H)
TBS – 1 322
3’ x 2’ x 2’
TBS – 1 422
4’ x 2’ x 2’
TBS – 1 622
6’ x 2’ x 2’

 

top
 
BIO SAFETY CABINET – CLASS II, TYPE A1
 

This Bio Safety Cabinet is a safer version of the Laminar Air Flow Cabinet. Here, 70% of air is re-circulated and 30% air is exhausted through a Blower at bottom of cabinet with +ve pressure in plenum at the back side. Provides product, environment and user safety.

 

 

MATERIAL OF CONSTRUCTION

Electro – galvanised (G.I) sheet metal with powder coat finish
CRCA sheet with powder coat finish
Water proof plywood with lamination
Fully Stainless steel

TECHNICAL SPECIFICATION

Cleanliness : Class 100
Particle retention : 0.3 micron & above
Filter Face Velocity : 90 ± 20 FPM
Standard : US Federal Standard 209 E
Noise Level : 65 dB ± 5 %
Illumination : 750 to 800 lumen
Power supply : 220 v single phase 50 cycle

APPLICATION

Most suitable for bacteriological, toxicology, where the presence of highly air borne particles, bacteria and viral need to be controlled to provide clean working condition.

 

MODEL NO.
Working area(L x D x H)
TBS-II / A 1 322
3’ x 2’ x 2’
TBS-II / A 1 422
4’ x 2’ x 2’
TBS-II / A 1 622
6’ x 2’ x 2’

 

top
 
BIO SAFETY CABINET – CLASS II, TYPE A2
 

This Bio Safety Cabinet is a safer version of the Laminar Air Flow Cabinet . Here, 70% Re-Circulation and 30% Exhaust of air is created. The Blower is placed on top of the cabinet with -ve pressure in plenum on the back side. Provides product, environment and user safety.

 

 

MATERIAL OF CONSTRUCTION

Electro – galvanised (G.I) sheet metal with powder coat finish
CRCA sheet with powder coat finish
Water proof plywood with lamination
Fully Stainless steel

TECHNICAL SPECIFICATION

Cleanliness : Class 100
Particle retention : 0.3 micron & above
Filter Face Velocity : 90 ± 20 FPM
Standard : US Federal Standard 209 E
Noise Level : 65 dB ± 5 %
Illumination : 750 to 800 lumen
Power supply : 220 v single phase 50 cycle

APPLICATION

Most suitable for bacteriological, toxicology, where the presence of highly air borne particles, bacteria and viral need to be controlled to provide clean working condition

 

MODEL NO.
Working area(L x D x H)
TBS-II / A 2 322
3’ x 2’ x 2’
TBS-II / A 2 422
4’ x 2’ x 2’
TBS-II / A 2 622
6’ x 2’ x 2’

 

top
 
BIO SAFETY CABINET – CLASS II, TYPE B1
 

This Bio Safety Cabinet is a safer version of the Laminar Air Flow Cabinet . Here, 30% Re-Circulation and 70% Exhaust of air is created. The Blower is positioned at bottom of cabinet with -ve pressure in plenum on both sides. Contaminated air will be filtered through HEPA, one at bottom and two on top. Provides product, environment and user safety.

 

 

MATERIAL OF CONSTRUCTION

Electro – galvanised (G.I) sheet metal with powder coat finish
CRCA sheet with powder coat finish
Water proof plywood with lamination
Fully Stainless steel

TECHNICAL SPECIFICATION

Cleanliness : Class 100
Particle retention : 0.3 micron & above
Filter Face Velocity : 90 ± 20 FPM
Standard : US Federal Standard 209 E
Noise Level : 65 dB ± 5 %
Illumination : 750 to 800 lumen
Power supply : 220 v single phase 50 cycle

APPLICATION

Most suitable for bacteriological, toxicology, where the presence of highly air borne particles, bacteria and viral need to be controlled to provide clean working condition.

 

MODEL NO.
Working area(L x D x H)
TBS-II / B 1 322
3’ x 2’ x 2’
TBS-II / B 1 422
4’ x 2’ x 2’
TBS-II / B 1 622
6’ x 2’ x 2’

 

top
 
BIO SAFETY CABINET – CLASS II, TYPE B2
 

This Bio Safety Cabinet is a Full 100% Exhaust version with –ve pressure in back plenum with blower on top for exhaust. Provides product, environment and user safety.

 

 

MATERIAL OF CONSTRUCTION

Electro – galvanised (G.I) sheet metal with powder coat finish
CRCA sheet with powder coat finish
Water proof plywood with lamination
Fully Stainless steel

TECHNICAL SPECIFICATION

Cleanliness : Class 100
Particle retention : 0.3 micron & above
Filter Face Velocity : 90 ± 20 FPM
Standard : US Federal Standard 209 E
Noise Level : 65 dB ± 5 %
Illumination : 750 to 800 lumen
Power supply : 220 v single phase 50 cycle

APPLICATION

Most suitable for bacteriological, toxicology, where the presence of highly air borne particles, bacteria and viral need to be controlled to provide clean working condition.

 

MODEL NO.
Working area(L x D x H)
TBS-II / B 2 322
3’ x 2’ x 2’
TBS-II / B 2 422
4’ x 2’ x 2’
TBS-II / B 2 622
6’ x 2’ x 2’

 

top
 
BIO SAFETY CABINET – CLASS III
 

This Bio Safety Cabinet is a Full 100% Exhaust version with –ve pressure in back plenum with blower on top for exhaust. Provides product, environment and user safety.

 

 

MATERIAL OF CONSTRUCTION

Electro – galvanised (G.I) sheet metal with powder coat finish
CRCA sheet with powder coat finish
Water proof plywood with lamination
Fully Stainless steel

TECHNICAL SPECIFICATION

Cleanliness : Class 100
Particle retention : 0.3 micron & above
Filter Face Velocity : 90 ± 20 FPM
Standard : US Federal Standard 209 E
Noise Level : 65 dB ± 5 %
Illumination : 750 to 800 lumen
Power supply : 220 v single phase 50 cycle

APPLICATION

Most suitable for bacteriological, toxicology, where the presence of highly air borne particles, bacteria and viral need to be controlled to provide clean working condition.

 

MODEL NO.
Working area(L x D x H)
TBS-III 322
3’ x 2’ x 2’
TBS-III 422
4’ x 2’ x 2’
TBS-III 622
6’ x 2’ x 2’

 

top
 